![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 508](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453508.webp)
The RMEP activation time is configured.
----End
(Optional) Configuring the Anti-Jitter Time During Alarm Restoration
By configuring the anti-jitter time during alarm restoration, you can suppress alarm flapping.
Context
Perform the following steps on each device:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
The MD view is displayed.
Step 3
Run:
ma
ma-name
The MA view is displayed.
Step 4
Run:
alarm finish time
time
The anti-jitter time during alarm restoration is configured.
----End
(Optional) Configuring the Anti-Jitter Time During Alarm Generation
By configuring the anti-jitter time during alarm restoration, you can suppress the alarm flapping.
Context
Perform the following steps on each device:
Procedure
Step 1
Run:
system-view
The system view is displayed.
Step 2
Run:
cfm md
md-name
The MD view is displayed.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
491