![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 677](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453677.webp)
Minor
Link
Event
Detection Method
Usage Scenario
Errored
frame
second
event
If errored frames occur in a second,
the second is called an errored frame
second. An errored frame second
event occurs if the number of errored
frame seconds detected by a device
during a specified period is greater
than or equal to a configured
threshold. The device then notifies its
remote device of the event.
This method is used to detect errored
frame seconds during data
transmission at the media access
control sublayer.
Select one or more detection methods to monitor links based on actual scenarios.
Procedure
l
Detect errored symbol events.
1.
Run:
system-view
The system view is displayed.
2.
Run:
interface
interface-type
interface-number
The view of an interface at one end of a link is displayed.
3.
Run:
efm error-code period
period
The period of detecting symbol errors is set on the interface.
By default, the period of detecting symbol errors is 1 second on the interface.
4.
Run:
efm error-code threshold
threshold
The threshold for the number of symbol errors that are detected in the specified period
is set on the interface.
By default, the threshold for the number of symbol errors that are detected in the
specified period is 1 on the interface.
5.
Run:
efm error-code notification enable
The interface is enabled to report symbol errors.
By default, an interface is disabled from reporting symbol errors.
l
Detect errored frame events.
1.
Run:
system-view
The system view is displayed.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
660