Index L-send R-send L-recv Unack L-loss R-loss L-loss-ratio R-loss-
ratio
------------------------------------------------------------------------------
--
1016 10 10 10 0 0 0 0.0000%
0.0000%
1017 10 10 10 0 0 0 0.0000%
0.0000%
1018 10 10 10 0 0 0 0.0000%
0.0000%
1019 10 10 10 0 0 0 0.0000%
0.0000%
1020 10 10 10 0 0 0 0.0000%
0.0000%
1021 10 10 10 0 0 0 0.0000%
0.0000%
------------------------------------------------------------------------------
--
Average Local-loss : 0 Average Local-loss Ratio :
0.0000%
Maximum Local-loss : 0 Maximum Local-loss Ratio :
0.0000%
Minimum Local-loss : 0 Minimum Local-loss Ratio :
0.0000%
Average Remote-loss : 0 Average Remote-loss Ratio :
0.0000%
Maximum Remote-loss : 0 Maximum Remote-loss Ratio :
0.0000%
Minimum Remote-loss : 0 Minimum Remote-loss Ratio :
0.0000%
Step 2
Configure single-ended proactive SLM on a PW between PEs.
1.
Enable PE2 to receive SLM frames.
# Configure PE2.
[PE2]
cfm md md1
[PE2-md-md1]
ma ma1
[PE2-md-md-ma-ma1]
loss-measure single-ended-synthetic receive test-id 1 time-
out 300
[PE2-md-md1-ma-ma1]
quit
[PE2-md-md1]
quit
2.
Enable PE1 to send SLM frames.
# Configure PE1.
[PE1]
cfm md md1
[PE1-md-md1]
ma ma1
[PE1-md-md1-ma-ma1]
loss-measure single-ended-synthetic continual send test-id
1 interval 1000
[PE1-md-md1-ma-ma1]
quit
[PE1-md-md1]
quit
3.
Verify the configuration.
Run the
display y1731 statistic-type
command on PE1 to view statistics about single-
ended proactive SLM.
<PE1>
display y1731 statistic-type single-synthetic-loss test-id 1
------------------------------------------------------------------------------
--
Index L-send R-send L-recv Unack L-loss R-loss L-loss-ratio R-loss-
ratio
------------------------------------------------------------------------------
--
1016 10 10 10 0 0 0 0.0000%
0.0000%
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
878