![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 860](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453860.webp)
AdminPw interface : --
AdminPw link state : --
2.
Configure basic Ethernet CFM functions and specify the MEP type as inward.
Configure basic Ethernet CFM functions on each PE. Specify the Ethernet CFM protocol
in the version of IEEE Standard 802.1ag-2007. Create an MD named
md1
and an MA
named
ma1
, and bind the MA to the VLL.
# Configure PE1.
<HUAWEI>
system-view
[HUAWEI]
sysname PE1
[PE1]
cfm enable
[PE1]
cfm version standard
[PE1]
cfm md md1
[PE1-md-md1]
ma ma1
[PE1-md-md1-ma-ma1]
map mpls l2vc 2 tagged
[PE1-md-md1-ma-ma1]
mep mep-id 1 interface gigabitethernet1/0/1.1 inward
[PE1-md-md1-ma-ma1]
mep ccm-send mep-id 1 enable
[PE1-md-md1-ma-ma1]
remote-mep mep-id 2
[PE1-md-md1-ma-ma1]
remote-mep ccm-receive mep-id 2 enable
# Configure PE2.
<HUAWEI>
system-view
[HUAWEI]
sysname PE2
[PE2]
cfm enable
[PE2]
cfm version standard
[PE2]
cfm md md1
[PE2-md-md1]
ma ma1
[PE2-md-md1-ma-ma1]
map mpls l2vc 2 tagged
[PE2-md-md1-ma-ma1]
mep mep-id 2 interface gigabitethernet1/0/1.1 inward
[PE2-md-md1-ma-ma1]
mep ccm-send mep-id 2 enable
[PE2-md-md1-ma-ma1]
remote-mep mep-id 1
[PE2-md-md1-ma-ma1]
remote-mep ccm-receive mep-id 1 enable
3.
Configure the 1DM reception function on PE2.
# Configure PE2.
[PE2-md-md1-ma-ma1]
delay-measure one-way receive mep 2
4.
Enable on-demand one-way frame delay measurement on the PW on a VLL network.
# Configure PE1.
[PE1-md-md1-ma-ma1]
delay-measure one-way send mep 1 remote-mep 2 interval
1000 count 20
[PE1-md-md1-ma-ma1]
quit
[PE1-md-md1]
quit
5.
Verify the configuration.
Run the
display y1731 statistic-type
command on PE2 to view the statistics about the
delay in unidirectional frame transmission.
<PE2>
display y1731 statistic-type oneway-delay md md1 ma ma1
Latest one-way delay statistics:
------------------------------------------------------------------------------
--
Index Delay(usec) Delay variation(usec)
------------------------------------------------------------------------------
--
1 10000 -
2 10000 0
3 10000 0
4 10000 0
5 10000 0
6 10000 0
7 10000 0
8 10000 0
9 10000 0
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
843