![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 747](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453747.webp)
–
If the local MEP has not learned the MAC address of the remote MEP, the
MAC address of the remote MEP must be specified to implement single-ended
frame loss measurement.
–
If the local MEP has learned the MAC address of the remote MEP, the ID of
the remote MEP can be used to implement single-ended frame loss
measurement.
l
Configure proactive single-ended frame loss measurement.
1.
Perform the following steps on the devices at both ends of a PW where proactive
single-ended frame loss measurement will be implemented:
a.
Run:
system-view
The system view is displayed.
b.
(Optional) Run:
y1731 pm-mode enable
Performance management (PM) to manage Y.1731 proactive performance
statistics is enabled. PM saves the statistics to generated statistics files and then
sends the files to the NMS.
By default, PM is disabled from managing Y.1731 proactive performance
statistics.
c.
(Optional) Run:
y1731_record-upload
A device is enabled to send Y.1731 proactive performance statistics files to a
server.
The
y1731 pm-mode enable
and
y1731_record-upload
commands are
mutually exclusive.
d.
Run:
cfm md
md-name
The MD view is displayed.
e.
Run:
ma
ma-name
The MA view is displayed.
f.
Run:
map mpls l2vc
vc-id
{
raw
|
tagged
}
The MA is bound to a specified L2VC.
g.
Run:
mep mep-id
The MEP is configured.
h.
Run:
measure-point
mep
mep-id
{
ac
|
pw
}
The measure point is configured.
By default, a measurement point for collecting Y.1731 statistics is a PW interface.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
730