![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 524](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453524.webp)
The OAM management view is displayed.
Step 3
Run the following command as required.
l
Run:
oam-bind ingress cfm md
md-name
ma
ma-name
egress
bfd-session
bfd-session-id
Ethernet CFM is configured to send fault messages to BFD.
l
Run:
oam-bind ingress bfd-session
bfd-session-id
egress
cfm
md
md-name
ma
ma-name
BFD is configured to send fault messages to Ethernet CFM.
l
Run:
oam-bind cfm md
md-name
ma
ma-name
bfd-session
bfd-session-id
The bidirectional transmission of fault messages between Ethernet CFM and BFD is
configured.
l
Run:
oam-bind ingress efm interface
interface-type
interface-number
egress
bfd-
session
bfd-session-id
EFM OAM is configured to send fault messages to BFD.
l
Run:
oam-bind ingress bfd-session
bfd-session-id
egress
efm
interface
interface-type
interface-number
BFD is configured to send fault messages to EFM OAM.
l
Run:
oam-bind efm interface
interface-type
interface-number
bfd-session
bfd-session-
id
The bidirectional transmission of fault messages between EFM OAM and BFD is configured.
l
Run:
oam-bind ingress cfm md
md-name
ma
ma-name
egress
mpls
oam
interface
tunnel
tunnel-number
Ethernet CFM is configured to send fault messages to MPLS OAM.
l
Run:
oam-bind ingress mpls oam
{
lsp-name
lsp-name
|
lsr-id
lsr-id
tunnel-id
tunnel-
id
}
egress
cfm
md
md-name
ma
ma-name
MPLS OAM is configured to send fault messages to Ethernet CFM.
l
Run:
oam-bind ingress efm interface
interface-type
interface-number
egress
mpls
oam
interface
tunnel
tunnel-number
EFM OAM is configured to send fault messages to MPLS OAM.
l
Run:
oam-bind ingress mpls oam
{
lsp-name
lsp-name
|
lsr-id
ingress-lsr-id
tunnel-id
tunnel-id
}
egress
efm
interface
interface-type
interface-number
MPLS OAM is configured to send fault messages to EFM OAM.
----End
Checking the Configurations
By viewing whether traffic on CEs is switched to a backup path, you can check whether the
configurations are successful.
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
507