Context
Dual-ended frame loss measurement is carried out continuously to permit proactive reporting
of frame loss or performance results.
Dual-ended frame loss measurement in VLL networking is usually deployed on end-to-end
MEPs. Frame loss statistics are collected based on the transmit and receive counters carried by
CCMs. Dual-ended frame loss measurement can be successfully performed only when the
remote MEP is in the Up state.
Procedure
l
Configure dual-ended frame loss measurement for a PW.
NOTE
Perform the following steps on the devices initiates dual-ended frame loss measurement.
1.
Run:
system-view
The system view is displayed.
2.
(Optional) Run:
y1731 pm-mode enable
Performance management (PM) to manage Y.1731 proactive performance statistics
is enabled. PM saves the statistics to generated statistics files and then sends the files
to the NMS.
By default, PM is disabled from managing Y.1731 proactive performance statistics.
3.
Run:
cfm md
md-name
The MD view is displayed.
4.
Run:
ma
ma-name
The MA view is displayed.
5.
Run:
map mpls l2vc
vc-id
{
raw
|
tagged
}
The MA is bound to a specified L2VC.
6.
Run:
mep mep-id
The MEP is configured.
7.
(Optional) Run:
measure-point
mep
mep-id
{
ac
|
pw
}
A measurement point for collecting Y.1731 statistics is configured.
By default, a measurement point for collecting Y.1731 statistics is a PW interface.
8.
Run:
remote-mep mep-id
mep-id
The remote MEP ID is configured.
9.
Run:
mep ccm-send enable
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
734