Checking the Configurations
After configuring link monitoring, you can check whether the link monitoring configuration
succeeds.
Prerequisites
The link monitoring configurations are complete.
Procedure
l
Run the
display efm
{
all
|
interface
interface-type interface-number
} command to check
link monitoring configurations on interfaces.
----End
Example
Run the
display efm
command to view link monitoring configurations on interfaces.
<HUAWEI>
display efm interface gigabitethernet1/0/0
Item Value
----------------------------------------------------------
Interface: GigabitEthernet1/0/0
EFM Enable Flag: enable
Mode: active
Loopback IgnoreRequest: no
OAMPDU MaxSize: 128
OAMPDU Timeout: 3000
OAMPDU Interval: 1000
ErrCodeNotification: enable
ErrCodePeriod: 1
ErrCodeThreshold: 1
ErrFrameNotification: enable
ErrFramePeriod: 1
ErrFrameThreshold: 1
ErrFrameSecondNotification: enable
ErrFrameSecondPeriod: 60
ErrFrameSecondThreshold: 1
Hold Up Time: 0
ThresholdEvtTriggerErrDown: enable
TriggerIfDown: disable
TriggerMacRenew: disable
RemoteMAC 00e0-fc7f-7258
Remote EFM Enable Flag enable
Remote Mode passive
Remote MaxSize 128
Remote Loopback Type: ignore
Remote Loopback IgnoreRequest: --
Remote Parser: loopback
Remote Multiplexer: discard
8.3.4 Configuring Remote Loopback
Remote loopback is used to test link connectivity and performance.
Context
On the network shown in
, remote loopback is configured on the interface connecting
the CE to the PE. The interface sends test packets to its remote interface. The packet loss ratio