![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 571](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453571.webp)
interface GigabitEthernet1/0/3
undo shutdown
portswitch
port trunk allow-pass vlan 2
#
cfm md md1 level 6
ma ma1
map vlan 2
mep mep-id 1 interface gigabitethernet 1/0/1 inward
mep ccm-send mep-id 1 enable
remote-mep mep-id 2
remote-mep ccm-receive mep-id 2 enable
#
return
Example for Associating Ethernet CFM with an Interface
In this example, by associating Ethernet CFM with an interface, you can detect a fault on the
link between a CE and a UPE through LACP.
Networking Requirements
As shown in
, a user network is connected to an ISP network through Router A and
Router B. Router A acts as the CE device. Router B acts as the UPE device. It is required that
the following be achieved:
l
The bandwidth for the user network to access the ISP network is 2000 Mbit/s and an inactive
link that serves as a backup is provided.
l
When the active link between the user network and the ISP network fails, the LACP module
on the interface can sense the fault within 50 ms and stop forwarding data on the active
link.
Figure 8-15
Diagram of associating Ethernet CFM with an interface
RouterB
GE1/0/1
GE1/0/2
GE1/0/1
GE1/0/3
GE1/0/2
GE1/0/3
RouterA
ISP network
Link aggregation group in
static LACP mode
Active link
Inactive link
User
network 1
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
554