![Huawei Quidway NetEngine40E Скачать руководство пользователя страница 911](http://html.mh-extra.com/html/huawei/quidway-netengine40e/quidway-netengine40e_configuration-manual-reliability_169453911.webp)
#
vlan batch 2
#
cfm version standard
cfm enable
#
interface GigabitEthernet1/0/1
portswitch
undo shutdown
port trunk allow-pass vlan 2
#
cfm md md3
ma ma3
map vlan 2
mep mep-id 3 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 3 enable
remote-mep mep-id 4
remote-mep ccm-receive mep-id 4 enable
test-id 1 mep 3 remote-mep 4
loss-measure single-ended-synthetic continual send test-id 1 interval 1000
#
return
l
CE2 configuration file
#
sysname CE2
#
vlan 2
#
cfm version standard
cfm enable
#
interface GigabitEthernet1/0/1
portswitch
undo shutdown
port trunk allow-pass vlan 2
#
cfm md md3
ma ma3
map vlan 2
mep mep-id 4 interface GigabitEthernet1/0/1 outward
mep ccm-send mep-id 4 enable
remote-mep mep-id 3
remote-mep ccm-receive mep-id 3 enable
test-id 1 mep 4 remote-mep 3
loss-measure single-ended-synthetic receive test-id 1 time-out 300
#
return
Example for Configuring an ETH-Test Function
Y.1731 ETH-test functions can be used in VLL, VPLS, and VLAN scenarios. This section
provides an example for configuring the ETH-test function for a VLL network.
Networking Requirements
, MEP1 is configured on an AC interface of PE1, and MEP2 is configured on an
AC interface of PE2. MEP1 initiates an ETH-test and sends test packets with a specified size
and code type at a specified rate and interval. Then check the number of packets MEP1 sends
and the number of packets MEP2 receives. If MEP1 sends more packets than MEP2 receives,
some packets have been dropped. Then MEP1 is configured to use the bisection method to
continue the test and send test packets at a lower rate. The bisection method is used to send test
HUAWEI NetEngine80E/40E Router
Configuration Guide - Reliability
8 Ethernet OAM Configuration
Issue 02 (2014-09-30)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
894