FUEL SYSTEM (PGM-FI)
6-106
INSPECTION
Remove the PAIR control solenoid valve (page 6-
105).
Check that the air should flow (A) to (B), only when
the 12 V battery is connected to the PAIR control
solenoid valve terminals.
Air should not flow when the battery is connected.
Measure the resistance between the terminals of
the PAIR control solenoid valve.
If the resistance is out of specification, replace the
PAIR control solenoid valve.
Install the PAIR control solenoid valve (page 6-105).
PAIR CHECK VALVE
REMOVAL/INSTALLATION
Remove the luggage lower box (page 3-16).
Remove the bolt, stay and cover.
Remove the PAIR check valve from the cover.
Remove the baffle plate from the cylinder.
PAIR SOLENOID VALVE
(A)
(B)
STANDARD: 20 – 24
Ω
(20
°
C/68
°
F)
COVER
BOLT/STAY
BOLT
BAFFLE PLATE
PAIR CHECK VALVE
maxiscooter-club.ru
Содержание NSS250A Reflex 2001-2007
Страница 68: ...MEMO maxiscooter club ru...
Страница 71: ...TECHNICAL FEATURES 2 3 BALANCER SEPARATE TYPE METAL BEARINGS REED VALVE CRANK ROOM maxiscooter club ru...
Страница 114: ...MEMO maxiscooter club ru...
Страница 140: ...MEMO maxiscooter club ru...
Страница 154: ...MEMO maxiscooter club ru...
Страница 156: ...FUEL SYSTEM PGM FI 6 2 FUEL SYSTEM PGM FI COMPONENT LOCATION 11 N m 1 1 kgf m 8 lbf ft maxiscooter club ru...
Страница 280: ...MEMO maxiscooter club ru...
Страница 294: ...MEMO maxiscooter club ru...
Страница 322: ...CYLINDER PISTON 10 2 CYLINDER PISTON COMPONENT LOCATION maxiscooter club ru...
Страница 366: ...MEMO maxiscooter club ru...
Страница 368: ...FINAL REDUCTION 12 2 FINAL REDUCTION COMPONENT LOCATION NSS250A shown 24 N m 2 4 kgf m 18 lbf ft maxiscooter club ru...
Страница 418: ...MEMO maxiscooter club ru...
Страница 450: ...MEMO maxiscooter club ru...
Страница 542: ...MEMO maxiscooter club ru...
Страница 554: ...MEMO maxiscooter club ru...
Страница 644: ...MEMO maxiscooter club ru...
Страница 707: ...25 1 25 25 WIRING DIAGRAMS NSS250S 25 3 NSS250A 25 4 maxiscooter club ru...
Страница 715: ...MEMO maxiscooter club ru...