INS-70
DUAL, TRIPLE, POKER DC Inverter : 4. Installation
Multi Liberty
DC Inverter
Fig. 3.2.7
Fig. 3.2.8
2. Suspension of Indoor Unit to threaded bars (M10)
3. Useful dimensions for installation
■
■
■
Insert each threaded bar into the “U” slot on each suspension bearing of Indoor Unit. “U” shape allows to
make little horizontal adjustments in Indoor Unit’s position, that is to centre it in the best way as regards
installation needs.
Suspend Indoor Unit to threaded bars and position it perfectly horizontally by using a spirit level. Adjust
height and horizontal position of Indoor Unit by lower fixing nuts, provided with washer.
When height and Indoor Unit’s horizontal position are correct, fasten each fixing upper nut (provided of
their washer, too).
Fasten nut
and lock nut
Spirit level
Threaded bar
Upper nut
Lower nut
Upper washer
Lower washer
Unit’s bearing
HRBU (206, 266, 356) X Models
Unit: mm
25
102
87
Air outlet
55
220
175
63
Pipe connection Gas side
206 X, 266 X Models:
(Ø9.52, 3/8”)
356 X, 536 X Models:
(Ø12.7, 1/2”)
Pipe connection
Liquid side (Ø6.35, 1/4”)
Drain hose (Ø25)
203
203
874
674
375
■
■
STEEL ROOF BEAM STRUCTURE (“L” SECTION ELEMENTS)
For suspending Indoor Unit, screw hanging bolts on metal frame directly.
Fig. 3.2.6
Indoor Unit’s
hanging bolts
Hanging screw bolt
Supporting angle steel