CF-10
DUAL, TRIPLE, POKER DC Inverter : 5. Control Functions
Multi Liberty
DC Inverter
5.4.7 EXV open angle for Indoor Unit #1 (Unit “A”). This parameter is displayed after that SW1 has been pressed
for the 13th time.
The displayed value, multiplied x 8, gives the actual value of EXV open angle.
5.4.8 EXV open angle for Indoor Unit #2 (Unit “B”). This parameter is displayed after that SW1 has been pressed
for the 14th time.
The displayed value, multiplied x 8, gives the actual value of EXV open angle.
5.4.9 EXV open angle for Indoor Unit #3 (Unit “C”). This parameter is displayed after that SW1 has been pressed
for the 15th time.
The displayed value, multiplied x 8, gives the actual value of EXV open angle.
5.4.10 EXV open angle for Indoor Unit #4 (Unit “D”). This parameter is displayed after that SW1 has been pressed
for the 16th time.
The displayed value, multiplied x 8, gives the actual value of EXV open angle.
Display
Outdoor air
temperature (°C)
Display
Outdoor air
temperature (°C)
Display
Outdoor air
temperature (°C)
58
14
76
23
94
32
59
14.5
77
23.5
95
32.5
60
15
78
24
96
33
61
15.5
79
24.5
97
33.5
62
16
80
25
98
34
63
16.5
81
25.5
99
34.5
64
17
82
26
100
35~40
65
17.5
83
26.5
110
40~45
66
18
84
27
120
45~50
67
18.5
85
27.5
130
50~55
68
19
86
28
140
55~60
69
19.5
87
28.5
150
60~65
70
20
88
29
160
65~70
71
20.5
89
29.5
72
21
90
30
73
21.5
91
30.5
74
22
92
31
75
22.5
93