CF-26
DUAL, TRIPLE, POKER DC Inverter : 5. Control Functions
Multi Liberty
DC Inverter
5.13.15 “TIMER ON” function. When system is stopped (OFF), it will be restarted (ON) after programmed set time
has elapsed.
5.13.16 “TIMER OFF” function. When system is ON, it will be stopped (OFF) after programmed set time has elapsed.
5.13.17 “TIMER ON-OFF” function. When system is OFF, it will be restarted after programmed set time has elapsed;
then, system will be stopped (OFF) after programmed set time has elapsed.
5.13.18 “TIMER OFF-ON” function. When system is ON, it will be stopped (OFF) after programmed set time has
elapsed; then, system will be restarted (ON) after programmed set time has elapsed.
Note:
The approximate degree in elapsed time calculation is of 1 minute each hour of Timer setting.
Important:
for right carrying out of “TIMER” operations, it is needed that IR remote control is always positioned
within max. 8 metres as regards Indoor Unit.
r
HSFU X Models
5.13.19 Max. time interval that can be programmed for Timer function is of 24 hours. If programmed time is 0.5
hours to 12.0 hours, setting is made by 30-minute steps.
If programmed time is 12.0 hours to 24.0 hours, setting is made by 60-minute steps.
5.13.20 Programmed settings occur on the basis of a real time clock, that displays current time. Therefore, first of
all it is absolutely necessary to set current time, before carrying out Timer settings.
5.13.21 “TIMER ON” function. When system is OFF, it will be restarted (ON) as soon as programmed set time is
reached.
5.13.22 “TIMER OFF” function. When system is ON, it will be stopped (OFF) as soon as programmed set time is
reached.
5.13.23 “TIMER ON-OFF” function. When system is OFF, it will be restarted (ON) as soon as programmed set time
is reached; then, system will be stopped (OFF) as soon as programmed set time is reached.
5.13.24 “TIMER OFF-ON” function. When system is ON, it will be stopped (OFF) as soon as programmed set time
is reached; than, system will be restarted (ON) as soon as programmed set time is reached.
Important:
for right carrying out of “TIMER” operations, it is needed that IR remote control is always positioned
within max. 8 metres as regards Indoor Unit.
5.14 “SLEEP” function for Energy Saving operation [HKEU X Models only]
5.14.1
“SLEEP” function is available in the following operation modes: Cooling mode, Heating mode and Auto
mode. It can be activated by pressing the special button (“SLEEP”) on IR remote control.
5.14.2 “SLEEP” in Cooling mode. During the first 2 hours, set temperature is increased by 1°C