Does error (Error Code) occur again?
Measure voltage on secondary side of transformer, on Outdor Unit’s power supply
PCB: are there 12~14V AC?
Error Code on Outdoor Unit
Outline of malfunction
E 5
Error of voltage to compressor
YES
Check power supply voltage. If the detected value is of about 220V, try to
disconnect the system from power supply and connect it again after some
minutes (reset of power supply).
NO
Is Gas side temperature sensor on Indoor Unit “D” properly connected?
Are sensor wirings OK?
Error Code on Outdoor Unit
Outline of malfunction
E 6
Malfunction of Gas side temperature sensor, on Indoor Unit “D”
YES
NO
Measure the sensor resistance. Considering temperature, does resistance value
correspond to the features indicated in R-T tables?
NO
YES
Restore wirings/connector of
sensor.
Replace Gas side temperature sensor on
Indoor Unit “D”.
Replace Outdoor Unit’s main
PCB.
Replace Outdoor Unit’s main
PCB.
• Troubleshooting flowcharts, referred to Error Codes displayed on Outdoor Unit: