GI-95
DUAL, TRIPLE, POKER DC Inverter : 1. General Informationi
Multi Liberty
DC Inverter
1.13 OPERATION IN EMERGENCY MODE/TEST
n
HIGHWALL TYPE MODELS (HKEU X)
Frontal panel
Emergency/Test
button
AUTO/COOL
•
Access to Emergency / Test button:
To reach the Emergency/Test button, lift the
frontal panel.
•
•
Opening the frontal panel:
Pull up the frontal panel at both ends till a
click is heard and the panel remain fixed. Do
not lift the panel any fur ther because the
hinges could get broken.
Closing the frontal panel:
Seize the frontal panel at both ends, and
push it down. Close the panel firmly.
• Operation in “AUTO” Emergency Mode:
If the Remote Controller is not available or its batteries are exhausted, nevertheless the air conditioner can
be started by pressing once the “AUTO/COOL” button with system OFF. In this way, Emergency operation
will be started in “AUTO” (Automatic) mode, and the air conditioner will operate in the most suitable mode
according to temperature conditions inside the room, with temperature set to 24°C.
•
Test of air conditioner in Cooling mode “(COOL”):
With system OFF, press twice the “AUTO/COOL” button. In this way, operation in Test mode will be started.
The system will start in forced Cooling mode (“COOL”), at “LOW” fan speed. For 30 minutes, room
temperature will not be detected, but protection functions will keep active. Then, operation will go on in
“AUTO” (Automatic) mode, with temperature set to 24°C.
Note 1:
Never use Test mode for normal operation of Air Conditioner.
•
End of operation in Emergency mode or Test mode:
Press twice the “AUTO/COOL” button during Emergency operation, or press it once during Test mode: the
system’s operation will be stopped (OFF).
Note 2:
Besides, to restore normal operation of system, you only need to use the remote controller.
•
Operation sequence referred to each pressing of “AUTO/COOL” button:
→
AUTO
→
COOL (Test mode)
→
OFF
→