Installation and Wiring
EIO0000001505 12/2014
95
Motion Relays
Base Station wiring:
IN15
Limit switch input (for button 5)
When IN15 is activated, the relay 7 is OFF
IN16
Limit switch input (for button 5 +7) When IN16 is activated, the relays 7 and 9 are OFF
IN17
Limit switch input (for button 6)
When IN17 is ON, the relay 8 is OFF
IN18
Limit switch input (for button 6 +7) When IN18 is ON, the relays 8 and 9 are OFF
IN_COM
Common output port (to be
connected to the other side of the
dry contact connected to the
IN7…IN18 inputs)
-
Label
Wiring description
Factory setting description
Label
Wiring description
Factory setting description
Motion relays (for motor axis X)
CC_X
Common for relays 1…3
-
CT_1
Output of motion relay 1
Command for motion direction 1
Relay is ON when button 1 or 1H is pressed
CT_2
Output of motion relay 2
Command for motion direction 2
Relay is ON when button 2 or 2H is pressed
CT_3
Output of motion relay 3
Command for high speed
Relay is ON when button 1H or 2H is pressed
Motion relays (for motor axis Y)
CC_Y
Common for relays 4…6
-
CT_4
Output of motion relay 4
Command for motion direction 1
Relay is ON when button 3 or 3H is pressed
CT_5
Output of motion relay 5
Command for motion direction 2
Relay is ON when button 4 or 4H is pressed
CT_6
Output of motion relay 6
Command for high speed
Relay is ON when button 3H or 4H is pressed
Motion relays (for motor axis Z)
CC_Z
Common for relays 7…9
-
CT_7
Output of motion relay 7
Command for motion direction 1
Relay is ON when button 5 or 5+7 is pressed
CT_8
Output of motion relay 8
Command for motion direction 2
Relay is ON when button 6 or 6+7 is pressed
CT_9
Output of motion relay 9
Command for high speed
Relay is ON when button 5+7 or 6+7 is pressed
Содержание eXLhoist
Страница 12: ...12 EIO0000001505 12 2014...
Страница 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Страница 52: ...52 EIO0000001505 12 2014...
Страница 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Страница 151: ...Diagnostic EIO0000001505 12 2014 151 Procedure to Leave the Diagnostic Mode Step Action 1 Power OFF the Remote Device...
Страница 177: ...eXLhoist Configuration Software EIO0000001505 12 2014 177 The diagram illustrates the use cases...
Страница 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Страница 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Страница 214: ...214 EIO0000001505 12 2014...