Safety
56
EIO0000001505 12/2014
Standards and Terminology
Overview
The technical terms, terminology, and the corresponding descriptions in this manual normally use
the terms or definitions in the relevant standards.
In the field of Wireless Remote Control System, this includes, but is not limited to, terms such as
safety function, safe state, fault, fault reset, failure, error, error message, warning, warning
message, and so on.
These standards include:
IEC 61508 Ed.2 series: Functional safety of electrical/electronic/programmable electronic
safety-related systems
IEC 62061 Ed.1.0: Safety of machinery - Functional safety of safety-related electrical,
electronic, and programmable electronic control systems
EN ISO 13849-1 & 2 Safety of machinery - Safety related parts of control systems
EC Declaration of Conformity
The EC declaration of conformity for the machine directive 2006/42/EC can be obtained on
www.schneider-electric.com.
Functional Safety Certification
The integrated safety functions are compatible with:
EN 15011: 2011
EN 14492-2: 2009
EN 14439: 2009
EN 13557: 2008
IEC 60204-1: 2009
IEC 60204-32: 2008
The listed standards set out safety-related considerations of Wireless Remote Control System
safety related in terms of the framework of the ISO13849-1 and ISO13849-2 standards.
The defined safety functions are:
SIL1, SIL2, and SIL3 capability in compliance with the IEC 61508 Ed.2 series.
Performance Level c, d, and e in compliance with ISO 13849-1.
Compliant with category 2, 3, and 4 of European standard ISO 13849-1.
Also refer to Safety Function Capability
.
The safety demand operating mode is considered to be high demand or continuous mode of
operation according to the IEC 61508-1 standard.
The functional safety certificate is accessible on www.schneider-electric.com.
Содержание eXLhoist
Страница 12: ...12 EIO0000001505 12 2014...
Страница 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Страница 52: ...52 EIO0000001505 12 2014...
Страница 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Страница 151: ...Diagnostic EIO0000001505 12 2014 151 Procedure to Leave the Diagnostic Mode Step Action 1 Power OFF the Remote Device...
Страница 177: ...eXLhoist Configuration Software EIO0000001505 12 2014 177 The diagram illustrates the use cases...
Страница 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Страница 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Страница 214: ...214 EIO0000001505 12 2014...