The motion/auxiliary relay specifications are described in the table:
Specifications
Details
Value
ZARB12H
ZARB12W
ZARB18H
ZARB18W
Number of motion/auxiliary relays
-
12
18
Normally open (N0) relays
-
12 (Q1…Q12)
16 (Q1…Q16)
Normally open + normally closed
(N0+NC) relays
-
0
2 (Q17, Q18)
Nominal output voltage
-
24…48 V
ac/dc ±20%
24…240 V
ac/dc ±20%
24…48 V
ac/dc ±20%
24…240 V
ac/dc ±20%
Relay type according to EN/IEC
60947-5-1
AC15
B300
DC13
R300
Maximum making and breaking
capacities
1 000 000 cycles for NO contacts
500 000 cycles for NC contacts
AC15 / AC current according to
EN/IEC 60947-5-1
24 Vac
1.08 A
48 Vac
0.54 A
120 Vac
-
0.22 A
-
0.22 A
240 Vac
-
0.11 A
-
0.11 A
Inrush
260 VA
Maintained
26 VA
Maximum making and breaking
capacities
1 000 000 cycles for NO contacts
500 000 cycles for NC contacts
DC13 / DC current according to
EN/IEC 60947-5-1
24 Vdc
0.1 A
48 Vdc
0.05 A
120 Vdc
-
0.02 A
-
0.02 A
240 Vdc
-
0.01 A
-
0.01 A
Make
5 VA
Break
5 VA
Minimum output current
6.8 mA with 24 Vdc
voltage
6.8 mA
Maximum operating rate
-
2 Hz
Содержание eXLhoist
Страница 12: ...12 EIO0000001505 12 2014...
Страница 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Страница 52: ...52 EIO0000001505 12 2014...
Страница 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Страница 151: ...Diagnostic EIO0000001505 12 2014 151 Procedure to Leave the Diagnostic Mode Step Action 1 Power OFF the Remote Device...
Страница 177: ...eXLhoist Configuration Software EIO0000001505 12 2014 177 The diagram illustrates the use cases...
Страница 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Страница 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Страница 214: ...214 EIO0000001505 12 2014...