Diagnostic
150
EIO0000001505 12/2014
Diagnostic Mode
Overview
To test the Wireless Remote Control System configuration, the ZART•D has a specific diagnostic
mode display.
Procedure to Activate the Diagnostic Mode
The diagnostic mode on the ZART•D indicates the inputs and relays states of the Base Station.
Diagnostic Display Description
In STOP mode, use the buttons 5 and 6 to alternate between the 3 screens:
Base Station information:
ID
Hardware version
Firmware version
Remote Device information:
ID
Hardware version
Firmware version
Remote Device battery information (only for Schneider-Electric use).
In START mode, the Remote Device displays dynamically the I/O status:
1
IN1...IN18 states: up for input = 1, down for input = 0
2
Relays 1...18 states: up for output = 1, down for output = 0
Step
Action
1
Go to STOP mode
.
2
Simultaneously press the buttons 1 and 2, and release immediately.
3
Less than 5 seconds later, simultaneously press the buttons 3 and 4.
4
Release the buttons 3 and 4.
Содержание eXLhoist
Страница 12: ...12 EIO0000001505 12 2014...
Страница 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Страница 52: ...52 EIO0000001505 12 2014...
Страница 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Страница 151: ...Diagnostic EIO0000001505 12 2014 151 Procedure to Leave the Diagnostic Mode Step Action 1 Power OFF the Remote Device...
Страница 177: ...eXLhoist Configuration Software EIO0000001505 12 2014 177 The diagram illustrates the use cases...
Страница 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Страница 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Страница 214: ...214 EIO0000001505 12 2014...