Safety
EIO0000001505 12/2014
71
Legal RFU (Recommendation for Use)
Overview
According to the machinery directive 2006/42/EC and the amendment - RECOMMENDATION
FOR USE n
°
CNB/M/11.050 rev02, functional test (automatic or manual) shall be performed within
the following test intervals:
At least every month for PL e with category 3 or category 4 (according to EN ISO 13849-1) or
SIL3 with HFT = 1 (according to EN 62061);
At least every 12 months for PL d with category 3 (according to EN ISO 13849-1) or SIL2 with
HFT = 1 (according to EN 62061).