Safety
EIO0000001505 12/2014
65
STOP Function
Overview
For general descriptions, refer to STOP function
The undesired event of the STOP function is masking of STOP activation.
The safe state of the STOP function is to open safety relays.
STOP function is a passive stop (function activated when an invalid frame is detected).
Function
Installation
IEC 60204-32
IEC 61508
IEC 62061
ISO 13849
STOP
category
SIL
SIL CL
Safety
category
PL
STOP
No UOC
Category 0
SIL2
SIL2 CL
Safety
category 3
PL d
With UOC
Category 1