Safety
EIO0000001505 12/2014
57
Basics
Functional Safety
Automation and safety engineering are 2 areas that were separate in the past but have recently
become more and more integrated.
The engineering and installation of complex automation solutions are greatly simplified by
integrated safety functions.
Usually, the safety engineering requirements depend on the application.
The level of requirement results from the risk and the hazard potential arising from the specific
application.
IEC 61508 Standard
The standard IEC 61508 functional safety of electrical/electronic/programmable electronic safety-
related systems covers the safety-related function.
Instead of a single component, an entire function chain (for example, from a sensor through the
logical processing units to the actuator) is considered as a unit.
This function chain must meet the requirements of the specific safety integrity level as a whole.
Systems and components that can be used in various applications for safety tasks with comparable
risk levels can be developed on this basis.
ISO13849 Standard or IEC62061 Standard
Designers can follow either EN ISO 13849-1 or EN 62061 to demonstrate conformity with the
Directive 2006/42/EC on machinery. These 2 new standards consider not only whether a fault will
occur, but also how likely it is to occur.
This means that there is a quantifiable, probabilistic element in compliance: machine builders must
be able to determine whether their safety circuit meets the required Safety Integrity Level (SIL) or
Performance Level (PL). Panel builders and designers should be aware that manufacturers of the
components used in safety circuits (such as safety detection components, safety logic solvers, and
output devices like contactors) must provide detailed data on their products.
Содержание eXLhoist
Страница 12: ...12 EIO0000001505 12 2014...
Страница 34: ...Wireless Remote Control System 34 EIO0000001505 12 2014...
Страница 52: ...52 EIO0000001505 12 2014...
Страница 146: ...Using The Wireless Remote Control System 146 EIO0000001505 12 2014...
Страница 151: ...Diagnostic EIO0000001505 12 2014 151 Procedure to Leave the Diagnostic Mode Step Action 1 Power OFF the Remote Device...
Страница 177: ...eXLhoist Configuration Software EIO0000001505 12 2014 177 The diagram illustrates the use cases...
Страница 200: ...eXLhoist Configuration Software 200 EIO0000001505 12 2014...
Страница 213: ...EIO0000001505 12 2014 213 Harmony eXLhoist EIO0000001505 04 2014 Appendices...
Страница 214: ...214 EIO0000001505 12 2014...