Order No. 2104 ..
Normal (under current,
this means opened)
inverted form.
This parameter is only visible if the
operating mode "Cooling" or "Heating
and cooling" is configured and not two-
level operation.
Output of the command
value basic level cooling
Inverted (under current, this
means closed)
Normal (under current,
this means opened)
At this point, it is possible to specify
whether the command value telegram
for the cooling basic level is output
normally or in inverted form.
This parameter is only visible if the
operating mode "Cooling" or "Heating
and cooling" is configured along with
two-level operation.
Output of the cooling
additional stage variable
Inverted (under current, this
means closed)
Normal (under current,
this means opened)
At this point, it is possible to specify
whether the command value telegram
for the cooling additional level is output
normally or in inverted form.
This parameter is only visible if the
operating mode "Cooling" or "Heating
and cooling" is configured along with
two-level operation.
Command value limit
deactivated
continuously activated
can be activated via object
The command value limit allows the
restriction of calculated command
values to the range limits "minimum"
and "maximum". The limits are
permanently set in the ETS and, if
command value limitation is active, can
be neither undershot or exceeded during
device operation.
The "Command value limit" parameter
defines the mode of action of the limiting
function. The command value limit can
either be activated or deactivated using
the 1-bit communication object
"Command value limit", or be
permanently active.
Command value limit
after reset
deactivated
activated
When controlling via the object, it is
possible to have the controller activate
the command value limit automatically
after bus voltage return or an ETS
programming operation. This parameter
defines the initialisation behaviour here.
In the "Deactivated" setting, the
command value limit is not automatically
activated after a device reset. A "1"
telegram must first be received via the
"Command value limit" object for the
limit to be activated.
In the "Activated" setting, the controller
activates the command value limit
automatically after a device reset. To
deactivate the limit a "0" telegram must
Page 130 of 171
Software "KNX CO2 sensor"
Parameters