Annotation Cursor position
Defines the cursor position when annotation button Abc is pressed.
•
Home position: Cursor home position.
•
Last used: Last used cursor position.
Clear Annotation on un freeze
Define which annotation (text, indicators, bodymarks) should be cleared
automatically when the system state is changed from freeze to unfreeze. Select
between:
•
Clear text on unfreeze: The text of the active layer is cleared automatically.
•
Clear indicators on unfreeze: All indicators of the image area are cleared
automatically.
•
Clear bodymarks on unfreeze: All bodymarks of the image area are cleared
automatically.
Text Auto Setup Controls
Application
Select
Application to change the Annotation application. The application select page
appears with the currently active application (yellow). It is only available when no
text key or small list key is activated.
Select the desired annotation application or press
Return to go back without any
changes.
Prev./Next Page
Go to the previous/next page.
Text/Small List Text
Each
Text key can be programmed with a text line (up to 24 characters). If more
than one text line is entered, the
Text key becomes a Small List Text key. Each
Small List Text key can be programmed with 2 or 3 text lines, each containing up to
24 characters. If only one small list word is entered, the key becomes a
Text key.
Small List
A new small list word can be entered or an existing word can be edited.
Delete
A selected/highlighted word can be deleted.
Save
All changes on pages 1-4 are saved to the library.
Return
Go back to the main setup page without saving any changes.
11.2.1.5 Clipboard
Controls
Clipboard Reload Save
Choose the desired option and
Copy Position.
11.2.1.6 Patient Info Display
Controls
Calculate DOC by GA
Select whether to automatically calculate the DOC (Date of Conception) when a GA
is entered in the current patient dialog.
Calculate Day of Cycle by LMP
Select whether to automatically calculate the Day of Cycle when a LMP is entered
in the current patient dialog.
Capitalize Letters in patient names Write patient name in capital letters (information header, …) when typing the patient
name in the current patient dialog.
Capitalize all Letters in PID
Select whether to capitalize all letters in the Patient Info Display or not.
Capitalize first letter in patient
names
Select whether the first letter of a patient name should be automatically capitalized.
Keep Sonographer Name
Select whether or not to keep the snographer's name.
System Setup
11-12
Voluson™ SWIFT / Voluson SWIFT+ Instructions For Use
5831612-100 Revision 4
Содержание Voluson Swift