85
Splice Mode
Parameter
Description
Fiber Information
Left
Fiber
Right
Fiber
Coating
Diameter
Sets the fiber coating diameter.
Clad
Diameter
Sets the fiber cladding diameter.
The change in the parameter can be confirmed by the display.
[Coating Diameter] [Clad Diameter]
Core
Diameter
Sets the fiber core diameter.
MFD
•When the MFD settings of the left and right fibers are different,
the ratio of the one MFD to the other MFD is used for estimating.
Normally, the fiber entered in the parameter [MFD-L] can be
placed on either the left or the right side.
•If the [Gapset Pos.] is shifted from “Center,” the operator may be
required to place the correct fiber in the specified side.
•When splicing the left and right fibers with the same MFD, both
the parameters [Left Fiber MFD] and [Right Fiber MFD] must be
set to the same value.
Cleave
Length
Sets the cleave length (bare fiber part length).
Setting of the Left Fiber is changed. Setting of the Right Fiber is changed.
≪
FSM-100M+/P+ only
≫
•
Use adequate electrodes according to the fiber diameter.
Splicing 501um and over fiber: Use ELCT3-25-LDF electrodes
Splicing 500um and under fiber: Use ELCT3-25 electrodes
•
Perform
[
Stabilize Electrodes] and [Arc Calibration] when
exchanging electrodes.
•
To prevent the electrode unit from damage by hitting the fiber
and electrode unit, set [Electrode Gap] to 1.5mm or larger when
splicing 800um and larger fibers.