62
Function Introduction
8.
Selective Reset Function
Normally, when the RESET key is pressed, the splicer resets all motors to the home
position and returns to the [READY] condition. This will happen if the RESET key is
pressed just briefly (for example, for 1 second or less). If the operator presses the
RESET key continuously for 3 seconds a reset selection menu appears as shown below.
This menu allows various options for selectively controlling which motors reset to
home position and which motors remain stationary and do not move during the reset
operation. This can be very useful for special splicer operations. The reset options are
shown at the bottom of the screen.
NOTE:
In certain conditions, the End-View mirror motor of the FSM-100M+/P+ splicer
models will be reset regardless of the reset menu selection. This may be required in order to
protect the End-View mirror.
9.
Jump Back to READY
During splicer operation, when the splicer reaches [PAUSE1], [PAUSE2], [PAUSE θ],
and [FINISH], it is possible to jump back to the “READY” condition without resetting
any motors. This action is taken by pressing the LEFT arrow key.
This function is normally disabled. To enable it, the [Jump back to Ready] parameter on
page 3 of the [Splice Settings] menu must be enabled, as shown below.
Selection
Description
Reset All
All motors are reset
None
No motors are reset except the
End-View mirror motor
(necessary to protect the mirror)
Only θ Motors
Only θ motors are reset
Follow Splice
Mode Settings
Motor reset is controlled by the
[Clamp Action], and the [Sweep
Initial Position], [Except Z
stages] and [Z Stages] stage
positions settings in the
[Fundamental Settings] section
of the [Edit Splice Mode] menu.
The [Jump Back to READY]
function must be enabled in
the [Splice Settings] menu
Reset Selection Menu