Splice Mode
[Special Function]
Parameter
Description
Next Action ([Next Action] setting when [Measurement Method] is [OFF])
Next Action
When [OFF] is selected as the Target [Measurement Method], the [Next
Action] parameter appears (and there will be no measurement
performed at the end of a step).
In this case, the [Next Action] is selected independently to determine
what action takes place when the step is completed.
Select a desired [Next Action] from the following choices:
[Finish]: Special Function process is terminated
[Next Step]: Proceed to next step in Special Function process
[Pause]: The splicer pauses at the end of the current step. This
allows the operator to select options for how to proceed.
NOTE:
Details concerning use of pause during Special Function
operation is shown at the end of the Special Function section
[Repeat]: Repeat current step
NOTE:
If [Repeat] is selected, a [Repeat Limit] parameter appears to
allow control of how many times the step cab be repeated.
[Jump]: Jump to another step in the Special Function process
NOTE:
If [Jump] is selected, a [Step Increment] parameter appears. This
enables control of how many steps forward or backward the process will
jump. [Step Increment] can be set to jump forward up to 9 steps or
backwards up to 9 steps.
Because [Jump] is selected for
[Next Action], the [Step
Increment] parameter is available
to control the step to which
process will jump
Because [Repeat] is selected for
[Next Action], the [Repeat Limit]
parameter is available to control
the maximum number of repeats