82
Splice Mode
Parameter
Description
Fundamental Settings
Electrode Gap
Sets the gap between electrodes
"3mm" is recommended for
splicing larger than 400μm
cladding diameter fiber.
A change in the parameter is
confirmed by the display.
V Height Shift
Sets height of V-groove.
Arc Calibration
Method
Select STD (Standard) or SP (Special) or NC (No Calibration)
STD (Standard)
Arc power is updated by arc calibration in all modes, and is
highlighted in white on the display.
SP (Special)
Arc power is updated by arc calibration in a selected mode, and is
highlighted in yellow on the display.
NC (No Calibration)
This item is highlighted in red.
Uneven Melt
Detection Thr.
Sets the detection threshold of "Uneven Melt At Fiber End" error.
For more detail, refer to [Special Arc Calibration Mode]
SP Arc
Calibration Ref
The splicer displays the parameter when [SP (Special)] is selected as
[Arc Calibration Method].
The parameter indicates Splice Mode number to refer to SP arc
power, or [None].
When [None] is selected, the splicer refers to SP arc power in the
same Splice Mode.
When a splice mode number is selected, the splicer refers to SP arc
power of the referenced splice mode.
Mode # option list for [SP Arc Calibration Ref] includes only the
modes that use [SP (Special)] as [Arc Calibration Method] as well as
[None] as [SP Arc Calibration Ref].
Auto Arc
Calibration
This function calibrates the arc power at splice. Whenever this
function is on, the arc power is automatically corrected. The
correction value is used in the next splice. Select fiber data.
[Fiber Data Learning]→[Auto Arc Calibration]
Arc Center
Compensation
The center of the arc discharge is calculated and the [Gapset Position]
is automatically adjusted by selecting ON.