120
Splice Mode
[Step 2]: The fiber is pulled constant in diameter for 2.00mm in length.
Set the parameters for [Step 2] in [Special Function] as table below.
i) Tapering by ZL/ZR motors
ii) Tapering by Sweep/ZR motors
Parameter
Arc
Arc
Arc Power
SP – 45 bit
SP – 45 bit
Start Time
0 ms
0 ms
Finish Time
T
2
= L
2
/V
L
= 2000/0.25
= 8000 ms
T
2
= L
2
/V
swp
= 2000/0.25
= 8000 ms
Parameter
Motor1
Motor2
Motor1
Motor2
Motor
ZL
ZR
Sweep
ZR
Direction
[ Reverse ]
[ Forward ]
[ Left ]
[ Reverse ]
Start Time
0 ms
0 ms
0 ms
0 ms
Finish Time
T
2
T
2
T
2
T
2
Initial Speed
V
L
= V
feed
/R
2
= 0.04/0.4
2
= 0.25
V
feed
V
Swp
= V
feed
/R
2
= 0.04/0.4
2
= 0.25
V
Z
= V
SWP
- V
feed
= 0.25 - 0.04
= 0.21
Acceleration
0.00000000
(
OFF
)
0.00000000
(
OFF
)
0.00000000
(
OFF
)
0.00000000
(
OFF
)
Acceleration
Type
[ Type 1 ]
[ Type 1 ]
[ Type 1 ]
[ Type 1 ]
L
2
: taper section length in [Step 2] = 2.0mm = 2000 um
R: taper ratio = wrist diameter/fiber diameter = 50/125 = 0.4
V
feed
: fiber feeding speed = 0.04 um/ms (default value)
i) Parameters when tapering by ZL/ZR motors
• If you are not able to taper as designed in the above settings, please change
the “arc power” or “fiber feeding speed”.
Содержание FSM-100M
Страница 2: ...FSM 100M P series FSM 100M P series ...