110
Splice Mode
Operation proceeds as follows:
(1)
When the SET key is pressed, the images below appear on the splicer monitors
(but the fibers do not move forward or appear on the screen).
(2)
By pressing the HELP key, the manual gap set menu appears as shown
below. Select the ZL motor for operation. Note that “ZL” will be displayed
at the top of the monitor to indicate the selected motor.
(3)
Press the Up/Down key to move the ZL motor forward or backward to align
the cleaved end of the left fiber with the left vertical grid line position.
Change motor speed from “Fast” to “Slow” as required by pressing the
ENT key. Use of the slow motor speed can help set the gap accurately.
(4)
Use the Right/Left key to select the ZR motor. Press the Up/Down key to
drive the right fiber forward to the proper gap position indicated by the right
vertical grid line.
Main Monitor