64
Function Introduction
11.
Synchronized
θL and θR
Motor Drive (FSM-100P/100P+ Only)
In some cases it may be useful to simultaneously rotate the left and right fibers in order
to inspect the fiber orientation before splicing or to inspect a completed splice without
risk of inducing torsion which might break the splice point. In the FSM-100P and
FSM-100P+ splicers it is possible to manually rotate the θL and θR motor in unison.
In any situation in which motors may be selected for operation, it is possible to select
θLR in order to perform synchronized operation of the left and right theta motors.
Motors driving operation may be performed by accessing [Motor Drive] in the
[Maintenance Menu] in the [PAUSE1], [PAUSE2], [PAUSE θ], and [FINISH] state.
Motor operation is also possible when using the [Precise Motor Drive] function, or
whenever performing manual splicing operations such as when [Gap Set] or the fiber
[Alignment Mode] are set to [Manual].
Operation is the same as manual operation of any individual motor. Use the Left/Right
arrow keys to select θLR. Use the UP/DOWN arrow keys to rotate the left/right fibers
in unison.