92
Splice Mode
Parameter
Description
Focus Settings
Focus LX
Views a fiber in one of the four focus settings.
The focus moves toward the core when the [Focus] value is increased.
“Auto” focus is strongly recommended, focusing independently if
they are different fiber types (dissimilar fiber splicing).
Focus LY
Focus RX
Focus RY
Prefuse
Prefuse Power
Prefuse arc power adjustment. If [Prefuse Power] is set too low, axial
offsets may occur if the cleave angles are off. If [Prefuse Power] is set
too high, fiber the end faces are exposed to excessive heat and splice
losses may be high.
Arc Calibration Method [STD] [SP] or [NC] are selected automatically.
Prefuse Time
Sets duration of the prefuse arc, which until the fibers begins stuffing.
Longer [Prefuse Time] is equivalent to higher [Prefuse Power].
Prefuse On
Time
During prefuse discharge, the heat supplied by the arc can be reduced by
changing the duty cycle, time on to time off of the discharge. The period
in which prefuse discharge is turned on is set in this field.
Prefuse Off
Time
Sets the time prefuse discharge is off.
Electrode
swing
Note:1
Set On or OFF. Below 2 items are needed when ON is selected.
Swing home
position
Note:1
This is to set swing home position.
Swing stroke
Note:1
This is to set electrode swing stroke
Overlap
Overlap
Sets the overlap amount for stuffing. [Overlap] should be small when the
[Prefuse Power] is weak or the [Prefuse Time] is short and large when
the [Prefuse Power] is strong or the [Prefuse Time] is long.
Stuff Speed
Set the Stuff Speed at the splice.
Setting is not available when [Auto Stuff Control] is [ON].
Note1: FSM-100M+/P+ Only
•Adjust the prefuse power by adjusting the [Prefuse On Time]
and [Prefuse Off Time].