112
Splice Mode
6-3.
Splicing Using Manual X/Y Alignment
This method is to manually align and splice fibers. The following procedure uses
automatic gap set of the fibers, as in the case of fully automatic splicing. However,
X/Y alignment is performed manually. For this method, the Gap Set parameter is set
to [Splicing], and other parameters of automatic gap set are utilized. The X/Y
Alignment Method is set to [PAS] and the Alignment Mode is set to [Manual], as
shown in the screen images below.
Operation proceeds as follows:
(1)
Press the SET key to drive the fibers forward automatically. The fibers stop
moving forward at the programmed gapset position. The screen images
below will appear.
Main Monitor
Sub Monitor
Содержание FSM-100M