9
Quick Start Guide
2-2.
Auto Arc Calibration
This function calibrates the arc power at splice. Whenever this function is on, the arc
power is automatically corrected. The correction value is used in the next splice.
See section [
2-3.
Estimate WSI/CSI
WSI or CSI can be selected for the method of estimating the MFD mismatch.
WSI method is suitable for fiber without depressed cladding like fluorine.
CSI method is suitable for fiber with depressed cladding.
※
WSI (Warm Splice Image)
※
CSI (Cold Splice Image)
See section [
2-4.
IPA Data (FSM-100P/P+ Only)
The splicer aligns theta by using the memorized IPA data of each fiber.
PAS is recommended for PANDA fiber alignment. This alignment method is fast and
accurate.
Please use the IPA mode when the standard alignment is not accurate.
※
PAS (Profile Alignment System)
※
IPA (Interrelation Profile Alignment)
See section [
IPA Data (FSM-100P/100P+ Only)
2-5.
End-View Observation System (FSM-100M+/P+ Only)
Optical fiber is observed in axial direction by a means of a mirror for fine alignment.
Uniquely structured fibers, such as PM, multi-core or non-circular fibers can now be
more precisely aligned. However, conventional PAS (Profile Alignment System) is
recommended for PANDA fiber splicing for fast and accurate alignment.
In the case that certain fibers show poor theta alignment with PAS, use IPA or
end-view observation system.
See section [
2-6.
Auto Time Comp.
(ECF/AUTO Control)
This function is used for G652 SMF splicing.
Arc power is optimized according to core concentricity-error.
If [ECF] is set to "OFF", this function is not available.
See section [
Содержание FSM-100M