78
Splice Mode
2.
Splice Option
This parameter is a set value common to all modes.
(1)
Press MENU key at [READY], [PAUSE] or [FINISH] state.
(2)
Move cursor by pressing
,
keys to a parameter to be changed.
(3)
Press ENT key to select parameter and change the parameter.
Splice Menu Parameter
Parameter
Description
Select Splice Mode
Refers to selected condition parameter.
Pause1
Pauses after Gap Set are measured.
Pauseθ
Pauses after θ when “ON".
Pause2
Pauses after ECF function when “ON”.
Auto Start
When [Auto Start] is "ON", the selected operation
starts automatically after the fibers have been loaded
and the wind protector closed.
Memory
Refers to a previously stored result.
For the FSM-100P/P+,
Pauseθ is displayed.
For the FSM-100M/M+
Pauseθ is not displayed and
is not available because
those splicers do not have θ
rotation capability