175
Error Message List
* You can select whether operator can continue to splice or not when some kinds of
error occur with the settings as following.
Error
Message
Reason
Solution
Large Cleave
Angle
Bad fiber
end-face.
Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
[Cleave Limit] is
set too low.
Increase the [Cleave Limit] to an adequate limit.
Cleave
Shape NG
Bud shape of
end-face.
Check the condition of the fiber cleaver. If the blade is
worn, rotate the blade to a new position.
Large Fiber
Angle
[Core Angle
Limit] is set too
low.
Increase the [Core Angle Limit] to an adequate limit.
(1.0 degree is standard)
Dust or dirt is on
the V-groove or
the clamp chip.
Clean the V-groove and clamp chip.
Clad diameter too
large.
In case of setting the clad diameter value of the fiber
greater than 250μm, set fiber holder with reverse
orientation. (100M/P only)
In case of coating
clamp.
Fiber coating has curl. If curl ratio is too big, fiber
angle error might happen. If possible, use the glass
clamping mode to increase stability.
Thin Fiber/
Fat Fiber
Inadequate arc
power
Calibrate the arc power with the [Arc Calibration]
function.
Prefuse power or
time is too high
If using the Other mode, adjust or initialize [Prefuse
Power] or [Prefuse Time] settings.
Insufficient
[Overlap] setting
If using the Other mode, adjust or initialize [Overlap]
setting.
The overlap value is fixed and cannot be adjusted in
“Normal Splice Mode”.
Too Tapering
Fiber
Too much fiber
taper.
Confirm setting of taper splice.
Bubble
Bad fiber
end-face.
Check the condition of fiber cleaver. When the blade
is worn, rotate the blade.
Prefuse power or
time is set too low
If using the Other mode, adjust or initialize [Prefuse
Power] or [Prefuse Time] settings.
Fiber
Separation
The fiber stuff
amount is
insufficient.
Check the [Overlap] settings in the splice mode.
The prefuse
power or prefuse
time is too high.
Check the [Prefuse Power] and [Prefuse Time]
settings in the splice mode.
Содержание FSM-100M