Splice Mode
(5)
After the manual gap set operation is completed, the fibers must be
manually aligned. Select a motor to be manually moved by pressing the
Right/Left key. The X Motor may be used to align the fibers in the X
camera view on the splicer monitor. The Y Motor can be used to align the
fibers in the Y camera view.
(6)
If rotational alignment of the fiber is required, select the θR motor to rotate
the right fiber, and the θL motor to rotate the left fiber.
(7)
After X/Y and θ alignment, check to ensure that the gap set position is still
correct. If necessary, use the ZL and ZR motors to readjust the gap set
positions to the fiber cleaved ends are accurately aligned with the 2 vertical
grid lines
(8)
The grid lines can be toggled ON and OFF by using the ESC key as shown
below.
(9)
When alignment is complete, press the key to splice the fibers. The fusion
arc will occur and the fibers will be automatically pushed together
according
Motor
UP
DOWN
ZL/ZR
Forward
Backward
X/Y
Upward
Downward
Focus X/Focus Y
Lens moves nearer fiber.
Lens moves away from fiber.
Theta L/Theta R
Forward
Backward
•During manual motor movement, the beeper sounds if the motor
reaches its limit and the stops. Press the opposite arrow key to move
the motor again.
•Displayed messages can be erased by pressing ENT key. Erased
messages can be recovered by pressing the ENT key again.
ESC
key