FR500A&FR510A Series Vector Control Inverter
- 63 -
F12.39
Acceleration/deceleratio
n time of simple PLC
reference 5
0
~
3
0
△
F12.40
Acceleration/deceleratio
n time of simple PLC
reference 6
0
~
3
0
△
F12.41
Acceleration/deceleratio
n time of simple PLC
reference 7
0
~
3
0
△
F12.42
Acceleration/deceleratio
n time of simple PLC
reference 8
0
~
3
0
△
F12.43
Acceleration/deceleratio
n time of simple PLC
reference 9
0
~
3
0
△
F12.44
Acceleration/deceleratio
n time of simple PLC
reference 10
0
~
3
0
△
F12.45
Acceleration/deceleratio
n timeof simple PLC
reference 11
0
~
3
0
△
F12.46
Acceleration/deceleratio
n time of simple PLC
reference 12
0
~
3
0
△
F12.47
Acceleration/deceleratio
n time of simple PLC
reference 13
0
~
3
0
△
F12.48
Acceleration/deceleratio
n time of simple PLC
reference 14
0
~
3
0
△
F12.49
Acceleration/deceleratio
n time of simple PLC
reference 15
0
~
3
0
△
F12.50
UP/DOWN function
selection of Multi-
reference
Unit’s place: Action selection when
power off
0:Zero clearing when power off
1:Hold when power off
00
×
Ten’s place: select if it can be
reduced to negative
0:Disable
1:Enable
F12.51
UP/DOWN speed of
Multi-reference
0.0
~
100.0% (0.0%Invalid)
0.0%
△
Group F13 Process PID
F13.00
PID setting
0: F13.01 digital setting
0
×
1:keypad potentiometer
2: AI1
3: Communication
4: Multi-Reference
5: DI7/HI pulse input
6: AI2
7: AI3
F13.01
PID digital setting
0.0
~
100.0%
50.0%
△
F13.02
PID feedback
0: AI1
0
×
1: AI2
2: Communication
3: AI1+AI2