FR500A&FR510A Series Vector Control Inverter
- 101 -
17
Set count value
attained
The terminal becomes ON when the count value reaches
the value set in F14.07.
18
Designated count
value attained
The terminal becomes ON when the count value reaches
the value set in F14.08. Refer to the specification of
parameter F14.07 and F14.08.
19
Length attained
The terminal becomes ON when the detected actual length
exceeds the value set in F14.04. Refer to the specification
of parameter F14.05
~
F14.07.
20
Under load alarm
When inverter under load, output ON signal
21
Brake Output
When the brake function selection is effective and reach
brake open condition, output signal ON
22
DI1
Output DI1 status
23
DI2
Output DI2 status
24
Reach the range of
FDT1
When running frequency reach the range of FDT1’s upper
limit and lower limit, output signal ON
25
Spindle orientation
completion
Inverter spindle orientation, when the error between the
encoder detection position and the setting location is less
than the location completion width and the duration reaches
the location completion time, the ON signal is considered to
be fixed and output
26
PID feedback loss
When PID feedback value is more than the high value of
PID feedback loss(F13.28) or less than the low value of PID
feedback loss(F13.24) and duration reaches their
accordingly detection time, then ON signal output.
27
Operation status
(exclude Jog)
When inverter is running(exclude jog running), the terminal
output valid
28
Communication
setting (address
2007h)
When the terminal is set to this function, the output state of
the terminal can be controlled through communication, and
the data format written is R2 R1 Y2 Y1. For example: if R1 is
set to 28, you can write 0100 to address 2007h, then R1's
status becomes valid, and write 0000, then it becomes
invalid
F05.04
Y1 output delay time
Range:0.0
~
6000.0s
Default:0.0s
F05.05
Y2 output delay time
Range:0.0
~
6000.0s
Default:0.0s
F05.06
Relay 1 output delay time
Range:0.0
~
6000.0s
Default:0.0s
F05.07
Relay 2 output delay time
Range:0.0
~
6000.0s
Default:0.0s
These four parameters define the delay response time of digital output terminals Y1 & Y2, relay 1
and relay 2.
F05.08
Enabled state of digital
output
Range:0000
~
1111
Default:0000
Unit's place: Y1
0: Positive logic; ON when current passes through
1: Negative logic; ON when no current passes through
Decade: Y2 (same as Y1)
Hundreds place: relay 1 output
0: Positive logic; ON when there is coil excitation
1: Negative logic; ON when there is no coil excitation
Thousands place: relay 2 output (same as relay 1)
Wiring diagram of digital output terminal is shown as Fig. 6-12: