FR500A&FR510A Series Vector Control Inverter
- 82 -
defined
The parameters are only for reference and cannot be edited.
F00.24
Dealer password
Range: 0
~
65535
Default: 0
F00.25
Setting operation time
Range: 0
~
65535h(0:
Invaild)
Default: 0
When total running time ≥F00.25, inverter will not work. When setting F00.24, need to unlock
F00.24 dealer passport, after time setting, need to input dealer passport to lock.
★
: Setting this parameter may cause that the inverter can’t work normally, please set carefully.
Group F01 Frequency command
Fig. 6-1
F01.00
Frequency source
selection
Range:0
~
7
Default: 0
0: Master frequency source
The frequency source is determined by master frequency source F01.01.
1: Auxiliary frequency source
The frequency source is determined by auxiliary frequency source F01.03.
2: Auxiliary
The frequency source is determined by Auxiliary.
3: Master - Auxiliary
The frequency source is determined by Master - Auxiliary.
4: MAX {Master, Auxiliary}
The frequency source is determined by MAX {Master, Auxiliary}.
5: MIN {Master, Auxiliary}
The frequency source is determined by MIN {Master, Auxiliary}.
6: AI1 ( Auxiliary)
The frequency source is determined by AI1*( Auxiliary).
7: AI2 ( Auxiliary)
The frequency source is determined by AI2*( Auxiliary).
F01.01
Master frequency source selection
Range:0
~
9
Default:1
0: Digital setting (F01.02)
When the inverter is powered on, the value of F01.02 is taken as the master frequency source.
1: Keypad potentiometer
2: Analog input AI1
AI1 and AI2 are (0
~
10V) voltage input and (0
~
20mA) current input programmable. Voltage or
current input can be selected through toggle switches AI1 and AI2 on control board.
When using external voltage/current analog input to the drive, the connection diagram is shown