FR500A&FR510A Series Vector Control Inverter
- 77 -
Err11: Motor overload
Err12: Inverter overload
Err13: External equipment fault
Err14: Module overheat
Err15: EEPROM read/write fault
Err16: Motor auto-tuning cancelled
Err17: Motor auto-tuning fault
Err18: Communication overtime
Error
Err19: PID feedback loss
Err20: Continuous running time
Reached
Err21: Parameter upload fault
Err22: Parameter download fault
Err23: Braking unit fault
Err24: Module temperature detection
disconnection
Err25: Load becoming 0
Err26: With-wave current limit fault
Err27: Inverter soft-start relay is off
Err28: EEPROM version is not
compatible
Err29: Instantaneous overcurrent
Err30: Instantaneous overvoltage
Err39: PTC motor temperature too
high
Err40: Setting operation time ends
Err41: Overload warning
U01.01
Running frequency
when the latest fault
occurred
0.00
~
Fup
0.00Hz
⊙
U01.02
Output current when the
latest fault occurred
0.0
~
3000.0A
0.0A
⊙
U01.03
Bus voltage when the
latest fault occurred
0
~
1200V
0V
⊙
U01.04
Cumulative running time
when the latest fault
occurred
0
~
65535h
0h
⊙
U01.05
Code of previous fault
Same as U01.00
0
⊙
U01.06
Running frequency
when previous fault
occurred
0.00
~
Fup
0.00Hz
⊙
U01.07
Output current when
previous fault occurred
0.0
~
3000.0A
0.0A
⊙
U01.08
Bus voltage when
previous fault occurred
0
~
1200V
0V
⊙
U01.09
Cumulative running time
when previous fault
occurred
0
~
65535h
0h
⊙
U01.10
Before-previous fault
code
Same as U01.00
0
⊙
U01.11
Running frequency
when before-previous
fault occurred
0.00
~
Fup
0.00Hz
⊙
U01.12
Output current when
before-previous fault
occurred
0.0
~
3000.0A
0.0A
⊙