FR500A&FR510A Series Vector Control Inverter
- 54 -
02: Command frequency
03: Output current
04: Output voltage
05: Output power
06: Bus voltage
07: +10V
08: keypad potentiometer
09: AI1
10: AI2
11: AI3
12: HI
13: Output torque
14: Ao communication given 1
15: Ao communication given 2
16: Encoder input
(FR510A only)
F07.02
Y2/HO output function
(when used as HO)
3
×
F07.03
AO1 offset
-100.0
~
100.0%
0.0%
△
F07.04
AO1 gain
-2.000
~
2.000
1.000
△
F07.05
AO1 filtering time
0.000
~
10.000s
0.000s
△
F07.06
AO2 offset
-100.0
~
100.0%
0.00%
△
F07.07
AO2 gain
-2.000
~
2.000
1.000
△
F07.08
AO2 filtering time
0.000
~
10.000s
0.000s
△
F07.09
HO maximum output
pulse frequency
0.01
~
100.00kHz
50.00kHz
△
F07.10
HO output filtering time
0.000
~
10.000s
0.010s
△
F07.11
Ho output encoder pulse
proportion 1
(FR510A only)
0.00
~
10.00
1.00
△
F07.12
Ho output encoder pulse
proportion 2
(FR510A only)
0.00
~
10.00
1.00
△
Group F08 Parameters of Motor 1
F08.00
Motor 1 type selection
0: Three phase asynchronous motors
0
×
1: PMSM (FR510A only)
2: Single phase asynchronous
motors (Remove capacity)
3: Single phase asynchronous
motors (No need to remove capacity)
F08.01
Power rating of motor 1
0.1
~
1000.0kW
Model
defined
×
F08.02
Rated voltage of motor 1
60
~
660V
Model
defined
×
F08.03
Rated current of motor 1
0.1
~
1500.0A
Model
defined
×
F08.04
Rated frequency of
motor 1
20.00
~
Fmax
Model
defined
×
F08.05
Rated speed of motor 1
1
~
30000
Model
defined
×
F08.08
Stator resistance R1 of
async motor 1
0.001
~
65.535Ω
Model
defined
×
F08.09
Rotor resistance R2 of
async motor 1
0.001
~
65.535Ω
Model
defined
×
F08.10
Leakage inductance L1
of async motor 1
0.01
~
655.35mH
Model
defined
×
F08.11
Mutual inductance L2 of
asynchronous motor 1
0.1
~
6553.5mH
Model
defined
×
F08.12
No-load current of
0.1
~
1500.0A
Model
×