FR500A&FR510A Series Vector Control Inverter
- 62 -
5: AI2
6: AI3
F12.17
Running mode of simple
PLC
Unit's place: PLC running mode
0: Stop after a single cycle
1: Continue to run with the last
frequency after a single cycle
2: Repeat cycles
00000
×
Ten’s place: started mode
0: Continue to run from the step of
stop (or fault)
1: Run from the first step
“multi-step frequency 0”
2: Run from the eighth step
“multi-step frequency 8”
3: Run from the fifteenth step
“multi-step frequency 15”
Hundreds place: power loss memory
0: Memory disabled on power loss
1: Memory enabled on power loss
Thousands place: unit of simple PLC
running time
0: Second (s)
1: Minute (min)
F12.18
Running time of step 0
0.0
~
6000.0s(h)
0.0s(h)
△
F12.19
Running time of step 1
0.0
~
6000.0s(h)
0.0s(h)
△
F12.20
Running time of step 2
0.0
~
6000.0s(h)
0.0s(h)
△
F12.21
Running time of step 3
0.0
~
6000.0s(h)
0.0s(h)
△
F12.22
Running time of step 4
0.0
~
6000.0s(h)
0.0s(h)
△
F12.23
Running time of step 5
0.0
~
6000.0s(h)
0.0s(h)
△
F12.24
Running time of step 6
0.0
~
6000.0s(h)
0.0s(h)
△
F12.25
Running time of step 7
0.0
~
6000.0s(h)
0.0s(h)
△
F12.26
Running time of step 8
0.0
~
6000.0s(h)
0.0s(h)
△
F12.27
Running time of step 9
0.0
~
6000.0s(h)
0.0s(h)
△
F12.28
Running time of step 10
0.0
~
6000.0s(h)
0.0s(h)
△
F12.29
Running time of step 11
0.0
~
6000.0s(h)
0.0s(h)
△
F12.30
Running time of step 12
0.0
~
6000.0s(h)
0.0s(h)
△
F12.31
Running time of step 13
0.0
~
6000.0s(h)
0.0s(h)
△
F12.32
Running time of step 14
0.0
~
6000.0s(h)
0.0s(h)
△
F12.33
Running time of step 15
0.0
~
6000.0s(h)
0.0s(h)
△
F12.34
Acceleration/deceleratio
n time of simple PLC
reference 0
0
~
3
0
△
F12.35
Acceleration/deceleratio
n time of simple PLC
reference 1
0
~
3
0
△
F12.36
Acceleration/deceleratio
n time of simple PLC
reference 2
0
~
3
0
△
F12.37
Acceleration/deceleratio
n time of simple PLC
reference 3
0
~
3
0
△
F12.38
Acceleration/deceleratio
n time of simple PLC
reference 4
0
~
3
0
△