F05.00
Y1 output function
00: No output
01: Drive is running
02: Fault output
03: Frequency-level detection FDT1
output
04: Frequency-level detection FDT2
output
05: Drive in 0Hz running 1(no output
at stop)
06: Drive in 0Hz running 2(output at
stop)
07: Upper limit frequency attained
08: Lower limit frequency attained
09: Frequency attained
10: Inverter is ready to work
11: Drive (motor) overloaded alarm
12: Inverter overheat warning
13: Current running time attained
14: Accumulative power-on time
attained
15: Consecutive running time
attained
16: PLC cycle completed
17: Set count value attained
18: Designated count value attained
19: Length attained
20: Under load alarm
21:Brake output
22: DI1
23: DI2
24:When reach the range of set
frequency(FDT1)
25: Spindle orientation completion
(FR510A only)
26: PID feedback loss
27: operation status (inching without
output)
28: communication setting (address
2007h)
1
×
F05.01
Y2 output function
3
F05.02
Relay 1 output function
2
×
F05.03
Relay 2 output function
11
×
F05.04
Y1 output delay time
0.0
~
6000.0s
0.0s
△
F05.05
Y2 output delay time
0.0
~
6000.0s
0.0s
△
F05.06
R1 output delay time
0.0
~
6000.0s
0.0s
△
F05.07
R2 output delay time
0.0
~
6000.0s
0.0s
△
F05.08
Enabled state of digital
output
Unit's place: Y1
0000
×
0: Positive logic
1: Negative logic
Ten’s place: Y2 (same as unit's
place)
Hundreds place: Relay 1 output
(same as unit's place)
Thousands place: Relay 2 output
(same as unit's place)
F05.09
Detection width of
frequency attained
0.00
~
20.00Hz
5.00Hz
×
F05.10
FDT1 upper bound
0.00
~
Fmax
30.00Hz
×
F05.11
FDT1 lower bound
0.00
~
Fmax
30.00Hz
×
F05.12
FDT2 upper bound
0.00
~
Fmax
30.00Hz
×