FR500A&FR510A Series Vector Control Inverter
- 154 -
Figure 8-1 (a) Remove the fan covers
Figure 8-1 (b) Remove the fan
Fan Installation
1.Figure 8-2 (a) shown in finger pressure to the inside of the fan under the lead terminal elastic
snaps, while a little harder vertically into the lead terminal, and then fan vertically into the slot.
2.Figure 8-2 (b), (c) as shown in the fan shroud assembly ramp into the hole at one end and the
other end to snap into place.
Tags
outward
Figure 8-2 (a) Install the fan leads
Figure 8-2 (b) Install the fan cover
Figure 8-2 (c) fixed in place
Note:
1, do not related jobs in the state power is turned on, otherwise there is danger of electric shock to
cause death. When conducting related operations, turn off the power and make sure the main circuit
DC voltage has dropped to a safe level, five minutes before the related operations.
2, the drive to work due to the loss caused by the heat sink temperature, in order to prevent burns,
do not touch the heat sink fins must be confirmed sufficiently cooled to a safe temperature below then
replace the cooling fan.
3, in order to ensure that the inverter can maximize performance, please use the original fan.
8.2.2 Other Devices
Replacement of other devices to maintain familiarity with technology and products are very strict
and must go through rigorous testing to be put into use after the replacement, so I do not recommend
the user to replace the other internal components, if indeed need to be replaced, please contact the
dealer where you purchased the product or our sales department.