Specifications
Unit
Enclosure size
1 (FS1), 2.5 A
Enclosure size
1 (FS1), 5 A
Enclosure size
1 (FS1), 10 A
Enclosure size
1 (FS1), 20 A
Enclosure size
2 (FS2), 40 A
Peak current (rms value) I
max
t
<2.65 s
A
rms
10
20
30
40
80
Nominal switching frequency
kHz
4/5
Possible switching frequency
kHz
8/10
Derating of nominal and peak
current with 8 kHz switching
frequency
%
65
Derating of nominal and peak
current with 10 kHz switching
frequency
%
55
Protective measures
–
Overload, short-circuit, and ground fault protection
Maximum output frequency
Hz
590
Functional safety
–
STO
Cooling
–
Integrated fan
Mounting
–
Wall-mounted on backplate using backlink connector
Number of motor connectors
–
1
Weight
kg
3.9
6.2
Dimensions
(W x H x D)
mm
84.3 x 471 x 270
134.3 x 471 x
270
11.3.5 Characteristic Data SDM 512
Table 124: Characteristic Data for SDM 512
Specifications
Unit
Enclosure size 1
(FS1), 2 x 2.5 A
Enclosure size 1
(FS1), 2 x 5 A
Enclosure size 1
(FS1), 2 x 10 A
Input
DC-link
V DC
565–680 ±10%
DC-link capacitance
µF
330
U
AUX
V DC
24/48 ±10%
U
AUX
current consumption (at 24 V DC)
A DC
2.3
U
AUX
current consumption (at 48 V DC)
A DC
1.2
Output
Output number of phases
–
3
Output voltage
V AC
V
IN
PSM
Rated current I
N
A
rms
2 x 2.5
2 x 5
2 x 10
Rated power P
N
kW
2 x 0.75
2 x 2.2
2 x 4
Specifications
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170
208 | Danfoss A/S © 2019.10