e3
0b
g4
54
.1
1
1
2
Illustration 144: STO Connectors on SDM 511/SDM 512
Table 147: Pin Assignment of STO Connectors on SDM 511/SDM 512
Connector name
Pins
De‐
scrip‐
tion
Notes
Rating/parameter
SDM511:
•
STO SDM
SDM512:
•
STO SDM1
•
STO SDM2
1
STO–
Used for STO output
voltage 1/2 to the input
of the PSM 510,
DAM 510, or SDM 511/2.
Nominal voltage: 24 V DC ±10%
Nominal current: Depends on the number of servo drives in
the application.
Maximum current: 1 A
Conductor cross-section range: 0.2–1.5 mm
2
(AWG 24–
AWG 16)
2
STO+
3
STO–
Used for STO input volt-
age 1/2.
4
STO+
NOTICE
-
Only PELV potential can be connected to the STO inputs.
11.7.10.2 STO Connectors on PSM 510
There is 1 input and 1 output STO connector on the Power Supply Module (PSM 510).