Table 82: Configuration parameters limits error (0x6383 / 0x164)
Code
PROFINET
®
code
Name
Severity (warn‐
ing/error/trip
lock)
Description
LCP name
0x6383
0x164
Configuration pa-
rameters limits er-
ror
Trip lock
≥1 parameter in the configuration parameter
set is out of limits: the parameter set is not
valid for this device.
conf par
lim
9.3.48 Power EEprom configuration error (0x6384 / 0x166)
This error is valid for PSM 510, DAM 510, ACM 510, and SDM 511/SDM 512.
Table 83: Power EEprom configuration error (0x6384 / 0x166)
Code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x6384
0x166
Power Eeprom config-
uration error
Trip lock
The power device Eeprom is corrupt or
incompatible with this control board.
conf par EE-
PROM
9.3.49 Brake chopper failure (0x7111 / 0x141)
This error is valid for PSM 510.
Table 84: Brake chopper failure (0x7111 / 0x141)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x7111
0x141
Brake chop-
per failure
Warning, error
The brake chopper is monitored during oper-
ation.
A brake failure has been detected by the
brake check function.
brake ch fail
9.3.50 Brake chopper overcurrent (0x7112 / 0x167)
This error is valid for PSM 510.
Table 85: Brake chopper overcurrent (0x7112 / 0x167)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x7112
0x167
Brake chopper
overcurrent
Trip lock
The brake chopper current ex-
ceeds the limit.
brake ch over-
curr
9.3.51 Brake resistor maximum power limit (0x7181 / 0x142)
This error is valid for PSM 510.
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 183
Danfoss A/S © 2019.10