Table 74: Inrush overtemperature: DC link (0x4293 / 0x13C)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x4293
0x13C
Inrush overtem-
perature: DC link
Error
Inrush fault.
Too many transitions into state
Operation
enabled
in a short time period.
inrush UDC
9.3.40 Inrush overtemperature AUX line (0x4294 / 0x13D)
This error is valid for DAM 510.
Table 75: Inrush overtemperature AUX line (0x4294 / 0x13D)
Code
PROFINET
®
code
Name
Severity (warning/
error/trip lock)
Description
LCP name
0x4294
0x13D
Inrush overtem-
perature AUX line
Error
Inrush fault.
Too many power-ups of the AUX voltage
have occurred within a short time period.
inrush
UAUX
9.3.41 Overtemperature: Motor (0x4310 / 0x108)
This error is valid for SDM 511/SDM 512.
Table 76: Overtemperature: Motor (0x4310 / 0x108)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x4310
0x108
Overtemperature:
Motor
Error
Overtemperature on mo-
tor.
overtemp motor
9.3.42 UAUX undervoltage (0x5112 / 0x109)
This error is valid for SDM 511/SDM 512.
Table 77: Short circuit (0x5112 / 0x109)
Code
PROFINET
®
code
Name
Severity (warning/error/
trip lock)
Description
LCP name
0x5112
0x109
UAUX under-
voltage
Error, trip lock
Undervoltage on auxiliary
voltage.
undervolt UAUX
9.3.43 Charge switch failure voltage (0x5121 /0x158)
This error is valid for PSM 510 and SDM 511/SDM 512.
Diagnostics
Operating Guide | VLT® Multiaxis Servo Drive MSD 510 System
AQ262450196490en-000101 / 175R1170| 181
Danfoss A/S © 2019.10
Содержание VLT MSD 510
Страница 1: ...Operating Guide VLT Multiaxis Servo Drive MSD 510 System...
Страница 2: ......